The
internal diluting aspirators we utilize in our Dilution
Probes are manufactured and calibrated to meet the highest
performance efficiencies on the market. This translates
into stability and lower dilution air consumption.
Reach a minimum vacuum of .47 bar (13.87"Hg) at a low
2.5 bar (36.25psi) dilution air pressure.
Maintain vacuum levels above the .47 bar through dilution
air pressures up to 6 bar.
Diluted sample flow rates in range of 4.5 to 12 l/min (dependent
on dilution air pressure setting).
Operating temperatures up to 750°F (400°C), or High
Temp versions to 1000°F (540°C)
Filters particulate using both coarse and fine filtering
methods
Reduces moisture content to levels below the dew point
Dilutes sample to more accurately measured concentrations
(dilution ratios from 12:1 to 350:1)
Precise low-flow sample flow rates (standard orifice sizes
from 20ml/min to 500ml/min)
Wetted parts from corrosion resistant Inconel-600®
Many critical orifice types available (Standard Glass, Quartz,
Monel-400, or Stainless-316)
In-situ Dilution Probe / Diluting Sampler -- Model DP-049-A:
Temperature Rating
Up to 750°F (400°C) | 1ea. Glass Critical Orifice
included
Description: In-situ Diluting Sample Probe, wetted
parts Inconel-600®, bolted support flange (4x bored
thru holes).
Cross-Ref old #797.302 (#797.302I, #797.302IB).
In-situ Dilution
Probe / Diluting Sampler
-- Model DP-049-C:
Temperature Rating
Up to 750°F (400°C) | 1ea.
Glass Critical
Orifice included
Description: In-situ Diluting Sample Probe, wetted
parts Inconel-600, threaded support flange.
Cross-Ref
old #797.303 (#797.303I), and #SONDIL001.
In-situ
Dilution Probe / Diluting Sampler
-- Model DP-049-A2:
Temperature Rating
Up to 1000°F (540°C) | 1ea. Monel® Critical
Orifice included
Description: High temperature In-situ Diluting Sample
Probe, wetted parts Inconel-600, bolted support flange (4x
bored thru holes).
Cross-Ref
old #797.305 (#797.305I, #797.305IB).
In-situ Dilution
Probe / Diluting Sampler
-- Model DP-049-C2:
Temperature Rating
Up to 1000°F (540°C) | 1ea. Monel® Critical
Orifice included
Description: High temperature In-situ Diluting Sample
Probe, wetted parts Inconel-600, threaded support flange.
Cross-Ref
old #797.306 (#797.306I), and #SONDIL017 (with -C3 for ball-end
quartz orifice).
Our
dilution probes require no changes to dilution probe controller
configurations and settings or analyzer settings (aside
from any typical adjustments required during your normal
diluting probe/CEMS calibrations) when retrofitting from
an old EPM dilution probe. We also offer a variety support
flange options. This will make the probe compatible with
any existing probe extension pipe assembly, and compatible
with new or old model probe heaters (using one of two types
of coarse inlet filters we offer).
Click Here
to view or download the in-situ probe brochure in printer
friendly PDF format.
|